ICS-6000

Thermo Scientific Dionex ICS-6000 HPIC System

The Thermo Scientific™ Dionex™ ICS-6000 HPIC™ System is a high-pressure ion chromatography system that provides an impressive combination of increased productivity, expanded capabilities, and improved performance. Modular versatility, functional integration, superior performance and the capability to operate continuously at up to 5000 psi culminate in the most advanced ion chromatography system.

DIONEX ICS-6000 SP SINGLE AND DP DUAL PUMPS SPECIFICATIONS
Pump
TypeDual-piston (in series), microprocessor controlled, constant stroke, variable speed, patented Isokinetic Eluent Precompression
ConstructionChemically inert, metal-free PEEK pump heads and flow path; compatible with aqueous eluents from pH 0–14 and reversed-phase solvents
Pressure RangeAnalytical: 0–35 MPa (0–5000 psi)
Capillary: 0–41 MPa (0–6000 psi)
Flow Rate RangeAnalytical: 0.000–10.000 mL/min with settable flow increments at 0.001 mL/min, without changing pump heads. Optional heads allow flow up to 22.4 mL/min. Capillary: 0.001–0.100 mL/min flow rate and up to 3.000 mL/min for pump priming
mL/min with settable flow increments at 0.0001 mL/min, typical working range of
5–30 μL/min
Flow Rate Precision (Analytical and Capillary)< 0.1%
Flow Rate Accuracy< 0.1%
Pressure Ripple< 1% at 1.0 mL/min/typical, < 0.2% (with damper) at 10 μL/min, < 1.0% (without
damper) typical
PressureNone required
Vacuum Degasser (Analytical and Capillary)Integrated, optional 1 channel for isocratic pump or 4 channel for quaternary pump
Piston Seal WashStandard, automatic operation
Gradient Formation (Analytical and Capillary)Quaternary low pressure (analytical only) or electrolytic eluent generation at high pressure
RFIC-EG GradientsAnalytical: 0.1–100 mM
Capillary: 0.1–200 mM
Gradient ProfilesAny combination of an unlimited number of linear, convex, and concave positive and negative gradient profiles
Gradient Proportioning Accuracy and Precision (Analytical Only)±0.5 at 2 mL/min
Gradient Mixing (Analytical Only)Passive mixers for 2 mm and 4 mm i.d. columns, optional
Eluent Generation (Analytical and Capillary)Optional eluent generation (RFIC-EG)
Eluent On/Off ValveElectrically actuated, standard
Leak SensorOptical, standard
System Software
SoftwareChromeleon 7.2 CDS software, supports Microsoft® Windows® 7, operating systems
Automated Procedure WizardsStandard feature
System Smart Startup and ShutdownStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party Instruments includingFully controls over 300 different instruments from more than 30 manufacturers, GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Signal ChannelsPump pressure
Data Trending PlotsAll numerical device parameters
System Status Virtual ChannelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands and ContitionalsStandard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
System Calibration StorageFactory, present and previous. Completely user selectable
Customized ReportingStandard feature with unlimited report workbooks
GLP ComplianceOptional
Physical Specifications
Power Requirements90–265 V ac, 47–63 Hz
Dimensions (h × w × d)41 × 23 × 56 cm (16 × 8.75 × 21.5 in.)
WeightSP: 20.4 kg (45 lb) — DP: 24.1 (55 lb)
Flow Path:All polymeric (PEEK), anion or cation configuration
DIONEX ICS-6000 EG ELUENT GENERATOR SPECIFICATIONS
Minimum and Maximum Eluent ConcentrationAnalytical: 0.1–100 mM
Capillary: 0.1–200 mM
Flow RatesAnalytical: 0.1–3.000 mL/min
Capillary: 0.001–0.030 mL/min
Eluent TypesAnalytical: KOH, LiOH, NaOH; Carbonate; Carbonate/Bicarbonate; MSA
Capillary: KOH, MSA
Maximum Operating PressureAnalytical: Dionex EGC III: 21 MPa (3000 psi); Dionex EGC 500: 35 MPa (5000 psi)
Capillary: 35 MPa (5000 psi)
Maximum Solvent Concentration (Analytical and Capillary)Cations: None
Anions: 25% methanol (KOH, NaOH and LiOH cartridges); None (Carbonate cartridge and EPM)
Gradient ProfilesStandard - any combination of an unlimited number of linear, convex and concave
positive and negative gradient profiles
Number of Cartridges SupportedTwo–dual cartridge support
RFIC Eluent Degasser (Analytical only)
Eluent degasser housed in the EG Module
System Software
SoftwareChromeleon 7.2 CDS software, supports Microsoft Windows 7 operating systems
Automated Procedure WizardsStandard feature
System Smart Startup and ShutdownStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party InstrumentsFully controls over 300 different instruments from more than 30 manufacturers,
including GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Signal ChannelsEluent concentration
Data Trending PlotsDevice numerical parameters plotted
System Status Virtual ChannelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands and ContitionalsStandard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
Eluent Cartridge Information StorageSerial number and expiration date
Customized ReportingStandard feature with unlimited report work
GLP ComplianceOptional package provides security, modification history, and electronic signatures
Physical Specifications
Power Requirements90–265 V ac, 47–63 Hz
Dimensions (h × w × d)41 × 23 × 56 cm (16 × 8.75 × 21.5 in.)
Weight25 kg (40 lb) without optional items
Flow PathAll polymeric (PEEK), anion or cation configuration
EluentsCarbonate and carbonate/bicarbonate combinations up to 20 mM MSA up to 34 mM
Flow Rates1.00–2.00 mL/min
Continuous Operation with 4 L of EluentUp to 28 days or 2000 samples, typically
Always on, Always Ready CapableStandard feature
Remains Fully Calibrated for Extended Periods of Time (≤ 28 Days):Standard feature, results are traceable to a single calibration
System WellnessConsumables usage monitoring for predictive maintenance
Maximum Operating Pressure21 MPa (3000 psi)
Operating Temperature Range4–40 °C
DIONEX ICS-6000 DC DETECTOR/CHROMATOGRAPHY COMPARTMENT SPECIFICATIONS
Standard DC Model:Upper Zone Temp Range: 18–40 °C (minimum temperature: ambient -15 °C);
(maximum temperature: ambient +20 °C)
Lower Zone Temp. Range: 10–70 °C (minimum temperature: ambient -15 °C)
(maximum temperature: ambient +50 °C)
Temperature Accuracy: ±0.15 °C
Temperature Stability: <0.05 °C
Temperature Precision: ±0.2 °C
Low Temperature DC ModelUpper Zone Temp. Range: 10–40 °C (minimum temperature: ambient -17 °C);
(maximum temperature: ambient +20 °C)
Lower Zone Temp. Range: 10–70 °C (minimum temperature: ambient -15 °C or
upper zone -20 C) (maximum temperature: ambient +50 °C)
Temperature Accuracy: ± 0.15 °C
Temperature Stability: <0.05 °C
Temperature Precision: +/-0.2 °C
Lower Zone (Analytical)Injection Valves: Up to two high-pressure valves,either 6- or 10-port, 2-position
Low Pressure Valves: Up to 2 inert, 2- or 3-way
Reaction Coil Heater (RCH): Holds two reaction coils
RCH Temperature Range: 5 °C above upper zone, 80 °C maximum
AutoPrep Kit: Dual loop for sample preconcentration
All valves and heater upgradable and field installable
Automation Manager (Optional – Analytical Only capillary chemistries)Injection Valves: Up to two high-pressure valves, either 6- or 10-port, 2-position
Low Pressure Valves: Up to 2 inert, 2- or 3-way
Reaction Coil Heater (RCH): Holds two reaction coils
RCH Temperature Range: 5 °C above upper zone, 80 °C maximum
AutoPrep Kit: Dual loop for sample preconcentration
All valves and heater upgradable and field installable
Capillary Dionex IC Cube Module
(Optional – but required for Injection)
One or two Dionex IC Cube models holding the folllowing:
Injection Valves: Up to two (one per cube( high-pressure valves, 4-port, 2-position.
An optional 6-port, 2-position valve is available to support large loop and concentrator
applications
EG Degasser
Column and Guard
Carbonate Removal Device
Capillary Suppressor (See Suppressor section)
Dionex IC Cube modules and cartridges are customer installable with pre-formed
tubing and color-coded labeling
Capillary column heater 15 to 80 °C)
Flow PathPlumbing configurations for 4 mm, 2 mm, and 0.4 mm columns, fully inert, PEEK
DetectorsAny combination of two conductivity or electrochemical detectors, upgradeable and field installable. Dual detectors can be operated simultaneously or independently.
Optional remote operation up to 3 m from instrument.
Analog Signal OutputTwo analog output channels, two 24 V relays, 2 TTL Out and 8 TTL In lines,
upgradable and field installable, optional
Leak DetectionOptical leak sensor standard
Application Control AutomationStandard. All DC modules come equipped with two switched AC controllers built-in to automate external devices and the ability to control up to six low pressure 2-way or 3-way valves for fluidic automation
DIONEX ICS-6000 DC DETECTOR/CHROMATOGRAPHY COMPARTMENT SPECIFICATIONS (CONTINUED)
Suppression
Non-Suppressed ConductivitySupported - both anion and cation
Suppressor Wear PartsNone. No valves, pumps, peristaltic pump tubing, or inline filters required
Chemical Suppression2 mm and 4 mm anion and cation membrane suppression available
Displacement Chemical Suppression2 mm and 4 mm anion and cation membrane suppression available
Electrolytic Suppression, Recycle Mode External Water Mode0.4 mm (with optional Dionex IC Cube module) 2 mm and 4 mm anion and cation.
Micro-membrane (2 mm and 4 mm) or capillary tube membrane (0.4 mm).
Salt ConverterAvailable in 2 and 4 mm versions
Dionex ACRS-ICEAvailable in 9 mm and 4 mm version
Carbonic Acid Removal for AnionsThermo Scientific™ Dionex™ ADRS 600 Anion Dynamically Regenerated Suppressor or Thermo Scientific™ Dionex™ ACRS™ Anion Chemically Regenerated Suppressor plus Thermo Scientific Dionex CRD 200 or Dionex CRD 300 Carbonate Removal Device for 2 and 4 mm versions, Therm Scientific™ Dionex™ ACES™ 300 Anion Capillary Electrolytic Suppressor plus Dionex CRD 200 Carbonate Removal Device (0.4 mm) for capillary suppressors
Suppressors
Suppression CapacitiesDionex ADRS 600 (4 mm) 200 μeq/min
Dionex ADRS 600 (2mm) 50 μeq/min
Dionex AERS 500 Carbonate (4 mm) 30 μeq/min .
Dionex AERS 500 Carbonate (2 mm) 7.5 μeq/min
Dionex AERS 500e (4 mm) 200 μeq/min
Dionex AERS 500e (2 mm) 50 μeq/min
Dionex CDRS 600 (4 mm) 100 μeq/min
Dionex CDRS 600 (2 mm) 35 μeq/min
Dionex CERS 500e (4 mm) 100 μeq/min
Dionex CERS 500e (2 mm) 35 μeq/min
Dionex ACES 2 μeq/min
Dionex CCES 1.5 μeq/min
Dionex ACRS (4 mm) 150 μeq/min
Dionex ACRS (2 mm) 37.5 μeq/min
Dionex CCRS (4 mm) 150 μeq/min
Dionex CCRS (2 mm) 37.5 μeq/min
Dionex ACES 300 (0.4mm) 2 μeq/min
Dionex CCES 300 (0.4 mm) 1.5 μeq/min
Suppressor Void VolumesDionex ADRS 600 (4 mm) < 50 μL
Dionex ADRS 600 (2mm) < 15 μL
Dionex AERS 500 Carbonate (4 mm) < 50 μL
Dionex AERS 500 Carbonate (2 mm) < 15 μL
Dionex AERS 500e (4 mm) < 50 μL
Dionex AERS 500e (2 mm) < 15 μL
Dionex CDRS 600 (4 mm) < 50 μL
Dionex CDRS 600 (2 mm) < 15 μL
Dionex CERS 500e (4 mm) < 50 μL
Dionex CERS 500e (2 mm) < 15 μL
DIONEX ICS-6000 DC DETECTOR/CHROMATOGRAPHY COMPARTMENT SPECIFICATIONS (CONTINUED)
SoftwareChromeleon 7.2 CDS software, supports Microsoft Windows operating systems
Automated Procedure Wizards2 mm and 4 mm anion and cation membrane suppression available
Electrolytic Suppression, Self-RegeneratingStandard feature
System Smart Startup and ShutdownStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party InstrumentsFully controls over 300 different instruments from more than 30 manufacturers,
including GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Signal ChannelsDetector signals, detector background signals, temperatures
Data Trending PlotsAll device numerical parameters plotted
System Status Virtual ChannelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands and ConditionalsStandard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
System Calibration StorageFactory, present, and previous. Completely user selectable
GLP ComplianceOptional
Physical Specifications
Power Requirements90–265 V ac, 47–63 Hz; (auto-sensing power supply; no manual voltage or frequency adjustment required)
Dimensions (h × w × d)Standard Model 44.5 × 42 × 57.5 cm (17.5 × 16.0 × 22.6 in.)
Low Temp Model 44.5 × 42 × 59.7 cm (17.5 × 16.0 × 23.5 in.)
WeightStandard Model 38 kg (84 lb)
Low Temp Model 43 Kg (94 lb)
Flow PathAll polymeric (PEEK), anion or cation configuration
DIONEX ICS-6000 CD CONDUCTIVITY DETECTOR SPECIFICATIONS
Electronics TypeMicroprocessor controlled digital signal processing
Cell Drive8 kHz square wave
LinearityR2≥0.999%
Resolution0.00238 nS/cm
Flow PathPlumbing configurations for 4 mm, 2 mm, and 0.4 mm columns, fully inert, PEEK
Output RangeDigital Signal Range: 0–18,000 μS/cm
Analog Signal Range: 0–18,000 μS/cm
Noise, Wet< 0.2 nS at 23 μS/cm background
< 0.1 nS at 1 μS/cm background
FilterRise times 0 to 10 s, programmable
Sample Rate1 to 100 Hz, user settable or automatic
Cell Temperature5 °C above DC upper zone temperature to 60 °C maximum. User settable, working
range is identical to settable range.
Cell Temperature Stability< 0.001 °C
Cell Temperature CompensationDefault 1.7% per °C; programmable from 0–3% per °C
Flow Cell Maximum Pressure10 MPa (1500 psi)
Flow Cell VolumeAnalytical: 0.7 μL
Capillary: 0.02 μL
Cell Electrodes
Cell Body
Heat Exchanger
Passivated 316 stainless steel. Compatible with MSA
Chemically inert polymeric material
Inert, tortuous-path for low axial dispersion
Software
SoftwareChromeleon 7.2 CDS software, supports Microsoft Windows 7, operating systems
Automated Procedure WizardsStandard feature
System Smart Startup and ShutdownStandard feature
System Wellness and Predictive PerformanceStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party InstrumentsFully controls over 300 different instruments from more than 30 manufacturers,
including GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Signal ChannelsElectrochemical and total electrochemical signals
Data Trending PlotsAll detector numerical parameters plotted
System Status Virtual ChannelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands Standard feature
and Conditionals
Standard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
System Calibration StorageFactory, present, and previous. Completely user selectable.
Customized ReportingStandard feature with unlimited report workbooks
GLP ComplianceOptional
Physical Specifications
Dimensions (h × w × d)6.9 × 16.7 × 9.9 cm (2.7 × 6.5 × 3.9 in.)
Weight400 g (1.6 lb)
DIONEX ICS-6000 ED ELECTROCHEMICAL DETECTOR SPECIFICATIONS
Electronics TypeMicroprocessor controlled digital signal processing
Electronic Noise (Wet Noise) (Analytical and Capillary)IPAD (Au electrode) < 30 pC at 10 mM KOH, DC Amperometry (GC) < 5 pA at catecholamine eluent
Potential Range-2.0 to 2.0 V in 0.001 V increments
Signal Range (Digital and Analog)Integrated Amperometry: 0.0008 pC to 200 μC
DC Amperometry: 0.00008 pA to 74 μA
Filter0–10 s response time, user settable
Control ModeLocal or remote control using relay closures or TTL, or control using Chromeleon
CDS software via DC module
Cell BodyTitanium body with narrow-bore PEEK inlet tubing for capillary format, titanium inlettubing for analytical format. Compatible with 0.2–0.6 mm i.d. columns (PEEK inlet), 2–7 mm i.d. columns (Ti inlet)
Working ElectrodesConventional: gold, glassy carbon, platinum, and silver
Disposable: gold, platinum, carbon, and silver
Reference ElectrodepH-Ag/AgCl combination, one piece design (Analytical and Capillary)
PdH, one piece design (Capillary Only)
AutorangingYes
Analog OutputUser selectable full scale of 10, 100, or 1000 mV
Cell Volume at Working Electrode< 0.2 μL
Maximum Cell Operating Pressure0.7 MPa (100 psi)
Software
Software Chromeleon 7.2 CDS software, supports Microsoft Windows 7, operating systems
Detection ModesDC amperometry, pulsed amperometry, and integrated amperometry. Detection modes include use of multiple waveforms and multiple integration times to optimize detection conditions for individual analytes. Integrated amperometry mode—unlimited changes to the waveform profile’s number of segments, duration of each segment, and voltage applied at each segment.
Automated Procedure WizardsStandard feature
System Smart Startup and ShutdownStandard feature
System Wellness and Predictive PerformanceStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party InstrumentsFully controls over 300 different instruments from more than 30 manufacturers,
including GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Signal ChannelsElectrochemical and total electrochemical signals
Data Trending PlotsAll detector numerical parameters plotted
System Status Virtual ChannelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands and ConditionalsStandard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
System Calibration StorageFactory, present, and previous. Completely user selectable.
Customized ReportingStandard feature with unlimited report workbooks
GLP ComplianceOptional
Physical Specifications
Dimensions (h × w × d) 6.9 × 16.7 × 9.9 cm (2.7 × 6.5 × 3.9 in.)
Weight 400 g (1.6 lb)
DIONEX ICS-SERIES PDA PHOTODIODE ARRAY SPECIFICATIONS
Optics
Photodiode Array1024 element
Pixel Resolution0.7 nm
LampsTungsten and deuterium
Optical Resolution1.0 nm
Wavelength Range190–800 nm
Electronics
Analog OutputsFour, 0–3 AU, 1000 mV range
Control ModesSoftware remote control through Chromeleon CDS software
Flow Cell
StandardPEEK or SST, 13 μL, 10 mm path length
Semi-PrepPEEK, 0.7 μL, 0.4 mm path length
Maximum Flow Operating Pressure300 psi (< 2 MPa) PEEK
500 psi (< 3 MPa) SST
Performance
Noise±10 μAU at 254 nm (flowing water, 2s rise time)
±15 μAU at 520 nm (flowing water, 2s rise time)
Drift< 500 μAU/h
Wavelength Accuracy±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter
Linearity> 2 AU
Physical Specifications
Power Requirements90–265 V ac, 47–63 Hz
Operating Temperature Range4–40 °C (40–104 °F)
Operating Humidity Range5–95% relative, noncondensing
Dimensions (h × w × d)17.4 × 44.4 × 50.3 cm (6.8 × 17.5 × 19.8 in.)
Weight18.1 kg (40 lb)
DIONEX ICS-SERIES VARIABLE WAVELENGTH DETECTOR SPECIFICATIONS
Optics
Optical System wavelength UV-visDual beam forward optics design (monochromator) single or multiple (4-channel)
detector options
Light SourceDeuterium lamp for UV range; tungsten lamp for visible range
Wavelength Range190 to 900 nm in 1 nm increments
Electronics
Analog Output Ranges (optional)0.001–3.0 AU
Rise Time0.00–4.55 s
Full-Scale Recorder Output1 V or 10 V
Data Collection rate up to 100 Hz Digital OutputFull dynamic autoranging digital absorbance signal output to Chromeleon CDS software
Control ModesSoftware remote control through Chromeleon CDS software
Flow Cells
CellPEEK
Cell Path Length10 mm (Standard and Capillary), 7 mm (Micro)
Cell Volume11 μL (Standard) 2.5 μL (Micro) 0.18 μL (Capillary)
Heat Exchanger Volume8.8 μL
Maximum Flow Cell Operating Pressure725 psi (5 MPa)
Performance
Wavelength Accuracy±1 nm
Linearity> 2 AU
Bandwidth6 nm at 254 nm
NoiseTypically - < ±2.5 × μAU at 254 nm
Drift< 0.1 m μAU/h at 254 nm
Physical Specifications
Power Requirements85–265 V ac, 47–63 Hz
Operating Temperature Range10–35 °C (50–95 °F)
Operating Humidity Range5–80% relative, noncondensing
Dimensions (h × w × d)15.2 × 44.4 × 50.3 cm (6.0 × 17.5 × 19.8 in.)
Weight15.4 kg (34 lb)
DIONEX AS-AP AUTOSAMPLER SPECIFICATIONS
Sample Capacity10 mL vials: 81
1.5 mL vials: 120
0.3 mL vials: 120
Well Plates: 288 (3 × 96 standard or deep well)
Well Plates: 1152 (3 × 384 standard well)
Minimum Sample Volume10 μL can be sampled from a 300 μL microvial; 20 μL can be sampled from a 500 μL
microvial
Maximum Injection Volume7500 μL
Variable Volume Range1–100 μL in 0.1 μL increments; 100–7500 μL in 1 μL increments
Injection Cycle Time (including sample prep such as dilution)15 s with sample overlap function; 30 s for a 5 μL full loop without sample overlap
Injection Modes Full Loop; Partial Loop; Limited Sample; Capillary
Sampling Technique Pull Mode; Push Mode
Injection PrecisionFixed Loop: < 0.3% RSD at 20 μL; Partial Loop: < 0.5% RSD at 20 μL
Capillary Mode: < 0.5% RSD at 0.4 μL
Dilution1:1 to 1:1000
AutoDilutionWith post-run functionality and Chromeleon AutoDilution License
Dilution Precision< 1.0% RSD for a 1:10 dilution
Carryover< 0.01% with 500 μL flush volume
Sample Tray Thermostatting4 °C to 60 °C, optional
Sample Conductivity and pHInline measurement of sample conductivity and pH with postrun functionality, optional
Dual Instrument SupportSequential (asynchronous) and Simultaneous modes, field upgradeable, optional
Sample DegassingCRD 200/300, upgradeable, user installable
Injection ValvesOne or two 2-position, 6- or 10-port
Diverter ValveOne 2-position, 6- or 10-port
Sample PreparationDilution, addition of internal standards, concentration/matrix elimination, derivatization,
etc.
Inline Sample FiltrationDual filter, backflush, optional
Software
SoftwareChromeleon 7.2 CDS software, supports Microsoft Windows 7, operating systems
Automated Procedure WizardsStandard feature
System Smart Startup and ShutdownStandard feature
System Wellness and Predictive PerformanceStandard feature
Application TemplatesStandard feature
Automation Support of 3rd Party InstrumentsFully controls over 300 different instruments from more than 30 manufacturers,
including GC, HPLC, and MS
Customizable System Control PanelsStandard feature
Power Failure ProtectionStandard feature
System Trigger Commands and ConditionalsStandard feature
Daily Audit TrailStandard feature
Sample Audit TrailStandard feature
System Calibration StorageFactory, present, and previous. Completely user selectable.
Customized ReportingStandard feature with unlimited report workbooks
GLP ComplianceOptional
Physical Specifications
Dimensions (h × w × d)44.5 × 35.9 × 51.6 cm (17.5 × 14.1 × 20.3 in.)
Weight< 25.2 kg (< 55.5 lb)
< 26.8 kg (< 59.0 lb) with sample temperature control
Power90–265 V ac, 47–63 Hz
Flow PathAll polymeric (PEEK), anion or cation configurations

Product Information PDF

ICS-6000

ICS_4000

The Dionex ICS-4000 HPIC System The World’s First Dedicated Capillary High-Pressure Reagent-Free Ion Chromatography System

The Thermo Scientific™ Dionex™ ICS-4000 HPIC™ system combines a new level of resolution and speed with capillary ion chromatography, delivering high-pressure IC on demand with a system that is always on and always ready for the next analysis.

Product Information PDF

ICS_4000

IC-Dionex-over all

IC INSTRUMENTS MADE FOR PROBLEM SOLVERS

As IC chromatographers, you are problem solvers, ensuring that everyone has access to healthy, clean and safe products and resources. Your IC instruments support you in this mission. The instruments in your laboratory must work seamlessly together to solve complex problems. Ion chromatography systems are highly interconnected within your laboratory ecosystem and must work reliably to keep your mission intact.
We offer an unsurpassed combination of products, support and solutions to address your current application needs and give you the confidence that you will be prepared to meet tomorrow’s challenges. Our products deliver the performance you have come to expect from a company that has been setting the standard for over 40 years. We are committed to providing you with the right tools to tackle the analytical demands that come your way.

Product Information PDF

IC-Dionex-over all

IC-Dionex-Aquion

Thermo Scientific Dionex Aquion Ion Chromatography System

The Thermo Scientific™ Dionex™ Aquion™ Ion Chromatography (IC) system provides a reliable foundation for IC analysis in a compact platform with the straightforward operation needed for budget-limited labs. Built with the aim of maintaining low operating costs, the Dionex Aquion IC system uses proven and reliable technologies to deliver results you can count on. The system is designed for ease of use, providing fast start up times and reliable, stable performance for demanding applications in environmental, food safety, and academic laboratories.

DIONEX AQUION IC SYSTEM SPECIFICATIONS
Analytical Pump and Fluidics
Type:Serial dual-reciprocating pistons, microprocessor-controlled constant stroke, variable speed
Construction:Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of
pH 0–14 and reversed-phase solvents
Pump Operating Pressure:0–35 MPa (0–5000 psi)
Flow Rate Range:0.00–5.00 mL/min without changing pump heads
Flow Precision:<0.1%, typically
Flow Accuracy:<0.1%, typically
Pressure Ripple:<1% at 13.8 MPa (2000 psi) and 1.0 mL/min
Eluent On-Off Valve:Standard
Piston Seal Wash:Dual-pump head, wash can be continuous when connected to rinse solution supply
Pressure Alarm Limits:Upper limit 0–35 MPa or 0–5000 psi in one unit (MPa or psi) increments; lower limit can be set up
to one unit lower than upper limit
Vacuum Degas:Yes, optional, automatic control
Eluent Bottles:Polypropylene, up to 4 L volume
Eluent Bottle Pressure:Not required
Injection Valve:6-port, 2-position Rheodyne valve, electrically activated
Columns Supported:2, 3, 4, and 5 mm i.d.; maximum length 250 mm analytical column with 50 mm guard column
Column Heater (Optional)
Operating Temperature Range:30 to 60 °C (86 to 140 °F); minimum 5 °C above ambient; settable range is equal to working range
Temperature Accuracy:±0.5 °C at sensor, at 40 °C
DIONEX AQUION IC SYSTEM SPECIFICATIONS (CONT’D)
Suppressors and Control
Chemical Suppression:2 mm and 4 mm anion and cation, membrane suppression bed types
Displacement Chemical Regeneration:2 mm and 4 mm anion and cation, membrane suppression bed types
Electrolytic Suppression:2 mm and 4 mm anion and cation; membrane suppression bed types available
Electrolytic Suppression with External Water Mode:2 mm and 4 mm anion and cation; membrane suppression bed types available
Current Control Range:Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor: 4 mm, 0–500 mA in 1 mA increments 2 mm, 0–150 mA in 1 mA increments
Thermo Scientific™ Dionex™ ERD™ 500 Electrolytically Regenerated Desalter: 0–500 mA (4 mm) and 0–150 mA (2 mm) in 1 mA increments
Thermo Scientific™ Dionex™ SRN™ Self-Regenerating Neutralizer: 0–500 mA in 1 mA increments
Salt Converter:Available in 2 and 4 mm versions
Carbonic Acid Removal for Anions:Dionex AERS 500 suppressor with Thermo Scientific Dionex CRD 200 Carbonate Removal Device for hydroxide eluents
Dionex AERS 500 suppressor with Dionex CRD 300 device for carbonate eluents
Non-Suppressed Chromatography:Yes, supported
Suppressor Wear Parts:None; peristaltic pump and inline filters not required
Suppression Capacity:Anions:
Dionex AERS 500 (4 mm): 200 μeq/min
Dionex AERS 500 (2 mm): 50 μeq/min
Dionex AERS 500e (4 mm): 200 μeq/min
Dionex AERS 500e (2 mm): 50 μeq/min
Dionex AERS 500 Carbonate (4 mm): 25 μeq/min
Dionex AERS 500 Carbonate (2 mm): 6.25 μeq/min
Thermo Scientific™ Dionex™ ACRS™ 500 Anion Chemically Regenerated
Suppressor (4 mm): 150 μeq/min
Dionex ACRS 500 suppressor (2 mm): 37.5 μeq/min
Cations:
Thermo Scientific™ Dionex™ CERS™ 500 Electrolytically Regenerated
Suppressor (4 mm): 110 μeq/min
Dionex CERS 500 suppressor (2 mm): 37.5 μeq/min
Thermo Scientific™ Dionex™ CCRS™ 500 Chemically Regenerated
Suppressor (4 mm): 100 μeq/min
Dionex CCRS 500 suppressor (2 mm): 25 μeq/min
Void Volumes:Dionex ERS 500 suppressor (4 mm): <50 μL
Dionex ERS 500 suppressor (2 mm): <15 μL
Dionex ERS 500e suppressor (4 mm): <50 μL
Dionex ERS 500e suppressor (2 mm): <15 μL
Dionex ERS 500 Carbonate suppressor (4 mm): <50 μL
Dionex ERS 500 Carbonate suppressor (2 mm): <15 μL
Dionex CRS 500 suppressor (4 mm): <50 μL
Dionex CRS 500 suppressor (2 mm): <15 μL
Conductivity Detector Electronics and Flow Cell
Type:Microprocessor-controlled digital signal processor
Cell Drive:8 kHz square wave
Linearity:1% up to 1 mS
Resolution:0.00238 nS/cm
Full-Scale Output Ranges:Digital signal range 0–15000 μS/cm
Analog signal range 0–15000 μS/cm
Electronic Noise:±0.1 nS when background conductivity is 0–150 μS/cm
±2 nS when background conductivity is 151–3200 μS/cm
Filter:Rise times from 0 to 10 s, user selectable
Temperature Compensation:Fixed at 1.7% per 1 °C at cell temperature
Temperature Range:Ambient +7 °C, 30 to 55 °C
Cell Electrodes:Passivated 316 stainless steel; compatible with MSA
Cell Body:Chemically inert polymeric material
Cell Volume:<1 μL
Heat Exchanger:Inert, tortuous path for low axial dispersion
Maximum Cell Operating Pressure:10 MPa (1500 psi)
DIONEX AQUION IC SYSTEM SPECIFICATIONS (CONT’D)
Autosampler
Automation Using Autosampler:Thermo Scientific Dionex AS-DV, AS-AP, AS-HV, or third-party autosamplers
Sequential/Simultaneous Injection:Yes, depending on autosampler capabilities
Automated Dilution:Yes, available with Dionex AS-AP autosampler
Dilution Factor, Dionex AS-AP Autosampler:1:1 to 1:1000
Dilution Time, Dionex AS-AP Autosampler:15 seconds with sample overlap
Inline Sample Degassing:Yes, optional with Dionex CRD 300/200 device
Inline Filtration:Yes, Dionex AS-DV Autosampler or inline filter
High Automation Flexibility:Conditionals using Chromeleon CDS software and post run features
System Software
Chromeleon CDS Software, is supported on Windows 7:
  • Automated Procedure Wizards

  • System Wellness and Predictive Performance

  • Data trending plots (numerical device parameters)

  • Virtual Column Simulator (evaluation mode standard, isocratic and gradient optional)

  • Multivendor automation support of 3rd party instruments (fully controls over 300 instruments from more than 30 manufacturers, including GC,
    HPLC, and MS)

  • 3-D Software for photodiode array, mass spectrometer, and electrochemical detectors (optional)

  • Customizable System Control Panels

  • System Status Virtual Channels

  • Power Failure Protection

  • Sequential Injection

  • System Trigger Commands and Conditionals

  • Daily Audit Trail

  • Sample Audit Trail

  • Multiple Network Control and Network Failure Protection (optional)

  • System Calibration Storage (factory, present, and previous; completely user selectable)

  • Customized Reporting (unlimited report workbooks)

  • Automated System Qualification (detailed, comprehensive qualification reports)
  • Physical Specifications
    Power Requirements:100–240 V ac, 50-60 Hz autoranging
    Operating Temperature:4–40 °C (40–104 °F); cold-room-compatible (4 °C) as long as system power remains on
    Operating Humidity Range:5–95% relative, noncondensing
    Control Modes:Full control through Chromeleon CDS software; alternative control through TTL or relay closures; two relay outputs, two TTL outputs, four programmable inputs
    USB Communication Protocol:One USB input; one built-in two-output USB hub
    Leak Detection:Built-in, optical sensor
    Dimensions (h × w × d):56.1 cm × 22.4 cm × 53.3 cm
    (22.1 in × 8.8 in × 21 in)
    Weight:24.5 kg (54 lb)
    Ordering Information
    To order in the U.S., call (800) 346-6390 or contact the Thermo Scientific office nearest you. Outside the U.S., order through your local Thermo Scientific office or distributor. Refer to the following part numbers.
    Dionex Aquion Ion Chromatography System with Software and PCPart Number
    Dionex Aquion Ion Chromatography System with Chromeleon CDS software, version SE and Windows 7 Workstation, without Degas22176-60101
    Dionex Aquion Ion Chromatography System with Chromeleon CDS software, version SE, Windows 7 Workstation, and Degas22176-60102
    Dionex Aquion Ion Chromatography System with Chromeleon CDS software, version SE, without Windows 7 Workstation, or Degas22176-60103
    Dionex Aquion Ion Chromatography System with Chromeleon CDS software, version SE and Degas, without Windows 7 Workstation22176-60104
    Optional Column Heater069564
    A Dionex Aquion/Chromeleon CDS software, version SE/Windows Workstation bundled package includes: a Dionex Aquion system with isocratic dual-piston pump, injection valve, heated conductivity cell, USB cable, Chromeleon CDS software, version SE, computer (with Windows 7), and USB dongle. Chromeleon CDS software, version SE comes with one SE timebase controlling one Dionex Aquion IC system. The Dionex Aquion IC system is supplied without a front control panel, and must be controlled through the Chromeleon CDS software. Consumables and CDS must be ordered separately.

    Product Information PDF

    IC-Dionex-Aquion

    TSQ-Quantis

    Quantitative throughput with confidence

    Your time is precious and you can’t afford delays. You need a system that you can trust to deliver results day after day. The TSQ Quantis MS enables robust, reliable quantitation with the sensitivity required to meet your workflow needs. Designed with ease-of-use in mind to ensure quality data from every user in every lab.

    Product Information PDF

    TSQ-Quantis

    TSQ-Altis

    No compromises: supreme quantitative performance

    Your samples are limited and precious. The Thermo Scientific™ TSQ Altis™ triple-stage quadrupole mass spectrometer makes the most of every attogram. Analytical labs demand robust, sensitive, and efficient targeted quantitation workflows to meet their scientific and business goals. The TSQ Altis MS is designed to help scientists achieve these goals every day, for every sample.

    Product Information PDF

    TSQ-Altis

    Q-Exactive-Focus-Orbitrap

    Transforming Routine Quantitation

    Designed for routine applications, the Thermo Scientific™ Q Exactive™ Focus hybrid quadrupole-Orbitrap mass spectrometer democratizes high resolution accurate mass (HRAM) analysis, enabling highly selective quantitative and qualitative analysis in a single affordable system.
    Built on the proven performance of the Q Exactive platform, the Q Exactive Focus mass spectrometer utilizes the same quadrupole design and Orbitrap™ technology for stable system operation and exceptional analytical performance, enabling labs performing routine analysis in a wide range of applications.

    Product Information PDF

    Q-Exactive-Focus-Orbitrap

    MSQ Plus Single Quadrupole

    Mass Detection Made Simple

    The world’s smallest mass spectrometer, the Thermo Scientific MSQ Plus Mass Detector, provides unsurpassed performance and ruggedness in an easy-to-use, highly sensitive instrument.

    Product Information PDF

    MSQ Plus Single Quadrupole

    Vanquish-UHPLC

    What is the Vanquish UHPLC System?

    The Vanquish system was built around the column and the user to deliver better separations, more results, and easier interaction. The Vanquish UHPLC system is an integrated, fully biocompatible system, addressing the needs of chromatographers performing state-of-the-art UHPLC.

    Product Information PDF

    Vanquish-UHPLC

    Vanquish-Flex-UHPLC

    Benefits of the Vanquish Flex UHPLC Systems

    In today’s challenging research and production environments, companies are being asked to cut costs without compromising quality, operational efficiency and performance. At the same time, there is significant pressure to increase productivity and drive innovation.
    The Vanquish Flex UHPLC systems are tools to enable you to meet these goals. Whether you need an LC or LC-MS solution, the flexibility of binary or quaternary solvent blending provides the most advanced performance through better separations, more results and easier interaction.

    Product Information PDF

    Vanquish-Flex-UHPLC